The effect of channel performance on a SOFC
Document Type
Conference Proceeding
Date of Original Version
12-1-2011
Abstract
In this paper we present a study of the of the steady state analysis of a Solid Oxide Fuel Cell Performance. We compare standard gas channels for air feeds to the same model with a porous channel for the air feed. The increased time constant on the air side has the potential to increase the efficiency of the SOFC The current density, along the electrolyte, the oxygen concentration in the gas channel and the porous cathode, and the potential in the cathode and the electrolyte are compared for the two models. All the simulations are treated at isothermal conditions and applied using COMSOL software. ©The Electrochemical Society.
Publication Title, e.g., Journal
ECS Transactions
Volume
33
Issue
39
Citation/Publisher Attribution
Song, Ke, and Harold Knickle. "The effect of channel performance on a SOFC." ECS Transactions 33, 39 (2011): 161-176. doi: 10.1149/1.3589926.